Aqua Swim and Spa

 

Affordable and space saving exercise/leisure pools and spas

 

    Company Home   Home    Ozonators    Pumps & Filters    Exercise Pools    Pool/Spa Combo    Spas     AquaPowerPac   

BaduJet    BaduStream  BaduStream-OverTheWall   AquaFrame  AquaSwimJet    Installation & Operation     Detailed Pool Diagram    

AquaSwimSpa Prices     AquaSwim'N'Spa Prices    AquaPhysio Therapy Prices   Aqua Spa Prices   Pictures   


AquaFrame:  The installation process can be simplified by using the AquaFrame, please refer to information regarding this option.

Our AQUASWIM' N'SPAS are very easy to install.  The pool arrives preassembled (including the swimjets and other inlet and outlets) on a truck and can be easily placed and supported per instructions outlined in this document.  The Powerpak is preinstalled on a fiberglass shell and basically needs a power connectiont.  Other work involves PVC pipe connection between the pool and the Powerpak.  The swimjets use 4" PVC piping and the filtration system uses 2" PVC piping.  Most if not all of the information which you may need are contain in the following paragraphs.  Please read the complete material and send us an email regarding any additional questions which you may have.

1.  AQUASWIM'N'SPAS UNIT SUPPORT INSTRUCTIONS

All spas should be installed on top of a 3 to 4 inch vermiculite or concrete pad. This pad should be at least the same size as the pool/spa that is being installed, i.e.: for an ASJ-SS-14 the pad should be 8'x 14'. 

Shoveling about 1/2" of sand on top of the concrete slab will make positioning and leveling much easier.

 

All swim spas must be supported with concrete blocks under all horizontal surfaces including swimjet manifold assemblies (as shown).

 

 All AQUASWIM'N'SPAS installed above ground or partial inground must be supported from under the wall stiffener with 4" x 4"s along each side (as shown).

 

For inground installation backfill by washing sand into all spaces around the unit. Add water to both sections of the unit before washing sand. To prevent flotation during backfilling, water level in swimming and spa compartments must be higher than the sand during the backfilling operation. After the backfilling has been completed, the unit may be drained for cleaning or maintenance if the ground water table is lower than the bottom of the swimming compartment. NOTE: All lumber has to be treated, as required in the (UBC)-1997.

Pressure test the plumbing system prior to completion of backfilling operation. To pressure test, run the unit for at least 2 hours on high speed. If no leaks are detected complete backfilling around the exposed plumbing.

All preplumbed AQUASWIM'N'SPAS are supplied with 25' of air tubing per air button. Plug the air tubing in the back of the air button located on the AQUASWIM'N'SPA console then plug the other end of the air tubing into the matching receptacle on the power pack.

Units with lights installed must have the light cord to the control box encased in conduit that is at least 10" above the water level of the spa.

2.  MATERIAL

Your AQUASWIM'N'SPA is manufactured of durable, reliable, thermoplastic; reinforced with tough, heavy-duty fibreglass. This thermoplastic has exceptional impact strength with superior resistance to the effects to sunlight, chemicals, and weathering. This same material is utilized in many other outdoor, maintenance-free products.

3.  CARE

Your AQUASWIM'N'SPA"A has an attractive, durable finish that stays virtually carefree. Most liquid shelf cleaners can be used to wipe scum, oil, and stains off the surface. Cleaners should be biodegradable, phosphate-free and neutral P.H.

DO NOT USE ABRASIVE PRODUCTS!

 

4.  MAINTENANCE

Chemical maintenance is practically the same as for a pool or spa. Chlorine or Bromine can be used to sanitize the water. CONSULT YOUR LOCAL POOL SERVICE COMPANY FOR PROPER MAINTENANCE PROCEDURES AND CHEMICAL TREATMENT IN YOUR AREA. Chemical treatment alone will not produce sanitary water. The filtration system, in proper operational condition, is required to attain sparkling clear, polished, sanitary water. Freechlorine level should be maintained between 1.0 and 1.5 PPM. PH level should be maintained at levels between 7.2 and 7.8. Low pH levels cause eye discomfort and corrosion of heater elements and metal parts. High pH levels cause cloudy water, scale formation, and eye discomfort.

AVOID EXTREME CHEMICAL IMBALANCES!

5.  FILTER

Filter elements should be cleaned periodically, when using cartridge filters. For other filter maintenance, consult installer for proper cleaning procedures. Dirty filters will cause pump to work inefficiently under increased pressures; thus not cleaning water for polished, sparkling clarity. Empty skimmer and pump strainer baskets periodically.

6.  AQUAPOWERPAK

Push-button air switches in the console cover control your equipment. Your AQUASWIM'N'SPA ­Equipment Pak consists of a combination pump/filter/heater unit. With two speeds it provides a maintenance cycle and on high speed, is the therapeutic Spa cycle. This pak is also equipped with a 4-HP. SwimJet pump to supply enough water flow to swim against. The pump/filter combination functions as a filtration unit for both the spa side and the poolside of the AQUASWIM'N'SPA on the low speed cycle of the pump. A swim-area valve is located at the pump. This valve directs filtered water to the pool or spa. The pool maintenance cycle is designed to overflow water from spa to pool. This overflow feature is designed into the swim area valve, introducing filtered water at all times, into the spa when the valve positioned on either "spa" or "swim" cycle. The maintenance/heating cycle is controlled by a time clock located in the control box. This may be set for proper maintenance and desired heating schedules.

7.  SUGGESTIONS & WARNINGS

1.      Do not stand in front of SwimJets when initiating jet-pump.

2.      Directing the SwimJets up and down or side to side controls water flow (current).

3.      Air may be introduced into jet flow by individual air controls at the console.

4.      Always enter and exit the AQUASWIM'N'SPA slowly and cautiously.

5.      Unsupervised use by children is prohibited.

6.      Do not use spa alone.

7.      Basic lifesaving equipment should be on hand at all times.

8.      For commercial installations, consult manufacturer prior to purchase.

9.      Do not empty the water from the AQUASWIM'N'SPA without consulting your installer ground water pressure may cause the unit to float.

10.  In climates subject to freeze consult your installer for proper winterizing procedures.

 

8.  APPROXIMATE BEARING PRESSURE

MODEL

SWIM AREA (PSF)

SPA AREA (PSF)

AS-RC-14

 

300

ASJ-SP-14

240

 

ASJ-SS-14

325

 

AS'N'S-16

225

300

AS'N'S-19

200

270

AS-7.5

 

375

AS-9

 

350

APT-9

 

500

APT-14

430

 

APT-19

400

 

 PRESSURE ON FOUNDATION WHEN USED ABOVE GROUND

 NOTE: When installed on an elevated structure, provisions must be made to support entire weight of unit and water.

 9.  STANDARD DATA

MODEL

WEIGHT

LENGTH

WIDTH

DEPTH

SWIMJET

AREA

SPA

AREA

SWIMJET

GAL.  *

SPA

GAL. *

TOTAL

GAL. *

AS-RG-14

700 lbs.

14' 0"

7' 6"

4' 0"

 

95 sq. ft.

 

960

960

ASJ-SP-14

800 lbs.

14' 0"

7' 6"

4' 0"

95 sq. ft.

 

1,400

 

1,400

ASJ-SS-14

800 lbs.

14' 0"

7' 6"

4' 0"

95 sq. ft.

 

1,100

 

1,100

ASINIS-16

900 lbs.

16' 0"

7' 6"

4' 0"

82 sq. ft.

28 sq. ft.

1,214

314

1,528

ASINIS-19

1100 lbs.

19' 0"

7' 6"

4' 0"

95 sq. ft.

30 sq. ft.

1,400

400

1,800

AS-7.5

425 lbs.

7' 6"

7' 6"

4' 0"

 

51 sq. ft.

 

750

750

AS-9

500 lbs.

9' 0"

7' 6"

4' 0"

 

61 sq. ft.

 

800

800

APT-9

600 lbs.

9' 0"

7' 6"

5' 0"

 

73 sq. ft.

 

1,150

1,150

APT-14

900 lbs.

14' 0"

7' 6"

5' 0"

115 sq ft.

 

2,100

 

2,100

APT-19

1200 lbs.

19' 0"

7' 6"

5' 0"

  155 sq ft.

 

3,040

 

 3,040

 * One gallon of water weighs 8.34 lbs.

10.  METRIC DATA

MODEL

WEIGHT

LENGTH

WIDTH

DEPTH

SWIMJET

AREA

SPA

AREA

SWIMJET

GAL.

SPA

GAL.

TOTAL

GAL.

AS-RG-14

317 kg

4.26 m

2.29 m

1.22 m

 

8.83 m2

 

3,634

3,634

ASJ-SP-14

362 kg

4.26 m

2.29 m

1.22 m

8.83 ml

 

5,300

 

5,300

ASJ-SS-14

362 kg

4.26 m

2.29 m

1.22 m

8.83 m2

 

5,300

 

5,300

AS'N'S-16

408 kg

4.86 m

2.29 m

1.22 m

7.62 m2

2.60 m2

4,595

1,188

6,783

AS'K'S-19

499 kg

5.79 m

2.29 m

1.22 m

8.83 m2

2.79 m2

5,300

1,515

6,815

AS-7.5

192 kg

2.28 m

2.29 m

1.22 m

 

4.47 m2

 

2,839

2,839

AS-9

226 kg

2.75 m

2.29 m

1.22 m

 

5.67 m2

 

3,406

3,406

APT-9

272 kg

2.75 m

2.29 m

1.52 m

 

6.78 m2

 

4,353

4,353

APT-14

408 kg

4.26 m

2.29 m

1.52 m

10.68 m2

 

7,950

 

7,950

APT-19

544 kg

5.79 m

2.29 m

1.52 m

14.40 m2

 

11,500

 

11,500

11.  STANDARD VOLUMES AND WEIGHTS OF APT UNITS

MODEL

WEIGHT

VOLUME

OF WATER

WEIGHT

OF WATER

TOTAL

WEIGHT

BASE AREA

LOAD ON

BASE

APT-9

600 lbs.

1,150 gal.

9,600 lbs.

10,200 lbs.

20.25 sq.ft.

500 psf

APT-14

900 lbs.

2,100 gal.

17,500 lbs.

18,400 lbs.

42.75 sq.ft.

430 psf

APT-19

  1200 lbs.

3,040 gal.

25,360 lbs.

26,560 lbs.

65.25 sq.ft.

400 psf

12.  METRIC VOLUMES AND WEIGHTS OF APT UNITS

MODEL

WEIGHT

VOLUME

OF WATER

WEIGHT

OF WATER

TOTAL

WEIGHT

BASE AREA

LOAD ON

BASE

APT-9

272 kg

4,353 It.

4,355 kg

4,627 kg

1.88 m2

2,461 m2

APT-14

408 kg

7,892 It.

7,938 kg

8,346 kg

3.97 m2

2,102 m2

APT-19

 544 kg

  11,506 It.

  11,503 kg

 12,407 kg

 6.06 m2

 1,988 m2